Спецификация USB.Rev1.0

       

Временные/Электрические Характеристики Шины


Таблица 7-4.  Электрические Характеристики DC

Parameter

Symbol

Conditions (Notes 1,2)

Min.

Max.



Unit

Supply Voltage:

Powered (Host or Hub) Port

VBUS

4.75

5.25

V

Bus-powered Hub Port

VBUS

4.40

5.25

V

Supply Current:

Powered Host/Hub Port (out)

ICCPRT

500

mA

Bus-powered Hub Port (out)

ICCUPT

100

mA

High Power Function (in)

ICCHPF

500

mA

Low Power Function (in)

ICCLPF

100

mA

Unconfig. Function/Hub (in)

ICCINIT

100

mA

Suspended Device

ICCS

500

mA

Leakage Current:

Hi-Z State Data Line Leakage

ILO

0 V< VIN<3.3 V

-10

+10

mA

Input Levels:

Differential Input Sensitivity

VDI

|(D+)-(D-)|, и Рисунок 7-4

0.2

V

Differential Common Mode Range

VCM

Includes VDI  range

0.8

2.5

V

Single Ended Receiver Threshold

VSE

0.8

2.0

V

Output Levels:

Static Output Low

VOL

RL of 1.5 kW to 3.6 V

0.3

V

Static Output High

VOH

RL of 15 kW to GND

2.8

3.6

V

Capacitance:

Transceiver Capacitance

CIN

Pin to GND

20

pF

Downstream Hub Port Bypass Capacitance

CHPB

Vbus to GND   (tantalum)

120

mF

Root Port Bypass Capacitance

CRPB

Vbus to GND    Note 9

1.0

10.0

mF

Terminations:

Bus Pull-up Resistor on Root Port

RPU

(1.5 kW ± 5%)

1.425

1.575

kW

Bus Pull-down Resistor on Downstream Port

RPD

(15 kW ± 5%)

14.25

15.75

kW

Cable Impedance and Timing:

Cable Impedance (Full Speed)

ZO

(45 W ±15%)

38.75

51.75

W

Cable Delay (one way)

TCBL

Рисунок 7-21

30

ns

<
Таблица 7-5.  Электрические Характеристики Полно Скоростных Источников

Parameter

Symbol

Conditions (Notes 1,2,3)

Min.

Max.

Unit

Driver Characteristics:

Transition Time:

   Rise Time

   Fall Time

TR

TF

Note 5, 6 and Рисунок 7-16

CL =   50 pF

CL =   50 pF

4

4

20

20

ns

ns

Rise / Fall Time Matching

TRFM

(TR/TF)

90

110

%

Output Signal Crossover Voltage

VCRS

1.3

2.0

V

Driver Output Resistance

ZDRV

Steady State Drive

28

43

W

Data Source Timings:

Full Speed Data Rate

TDRATE

Ave. Bit Rate

(12 Mb/s ± 0.25%)

11.97

12.03

Mbs

Frame Interval

TFRAME

1.0 ms ± 0.05%

0.9995

1.0005

ms

Source Differential Driver Jitter

   To Next Transition

   For Paired Transitions

TDJ1

TDJ2

Note 7, 8 and Рисунок 7-29

-3.5

-4.0

3.5

4.0

ns

ns

Source EOP Width

TEOPT

Note 8 and Рисунок 7-30

160

175

ns

Differential to EOP transition Skew

TDEOP

Note 8 and Рисунок 7-30

-2

5

ns

Receiver Data Jitter Tolerance

   To Next Transition

   For Paired Transitions

TJR1

TJR2

Note 8 and Рисунок 7-31

-18.5

-9

18.5

9

ns

ns

EOP Width at receiver

   Must reject as EOP

   Must accept as EOP

TEOPR1

TEOPR2

Note 8 and Рисунок 7-30

40

82

ns

ns





Таблица 7-6. Электрические Характеристики Низко Скоростных Источников

Parameter

Symbol

Conditions (Notes 1,2,4)

Min.

Max.

Unit

Driver Characteristics:

Transition Time:

   Rise Time

   Fall Time

TR

TF

Note 5, 6 and Рисунок 7-16

CL =   50 pF

CL = 350 pF

CL =   50 pF

CL = 350 pF

75

75

300

300

ns

ns

ns

ns

Rise/Fall Time Matching

TRFM

(TR/TF)

80

120

%

Output Signal Crossover Voltage

VCRS

1.3

2.0

V

Data Source Timings:

Low Speed Data Rate

TDRATE

Ave. Bit Rate

(1.5 Mb/s ± 1.5%)

1.4775

1.5225

Mbs

Source Differential Driver Jitter

 Host (Downstream):

   To Next Transition

   For Paired Transitions

 Function (Upstream):

   To Next Transition

   For Paired Transitions

TDDJ1

TDDJ2

TUDJ1

TUDJ2

Note 7, 8 and Рисунок 7-29

-75

-45

-95

-150

75

45

95

150

ns

ns

ns

ns

Source EOP Width

TEOPT

Note 8 and Рисунок 7-30

1.25

1.50

ms

Differential to EOP transition Skew

TDEOP

Note 8 and Рисунок 7-30

-40

100

ns

Receiver Data Jitter Tolerance

 At Host (Upstream):

   To Next Transition

   For Paired Transitions

At Function (Downstream):

   To Next Transition

   For Paired Transitions

TUJR1

TUJR2

TDJR1

TDJR2

Note 8 and Рисунок 7-31

-152

-200

-75

-45

152

200

75

45

ns

ns

ns

ns

EOP Width at receiver

   Must reject as EOP

   Must accept

TEOPR1

TEOPR2

Note 8 and Рисунок 7-30

330

675

ns

ns

<






Таблица 7-7. Электрические Характеристики Концентратора/Повторителя

Parameter

Symbol

Conditions (Note 2)

Min.

Max.

Unit

Hub Characteristics

 (Full Speed):


Driver Characteristics

  (Refer to Таблица 7-5)

Root port and Downstream ports configured as Full Speed

Hub Differential Data Delay

    (with cable)

    (without cable)

THDD1

THDD2

Note 3, 7, 8

and Рисунок 7-32

70

40

ns

ns

Hub Differential Driver Jitter   (including cable)

   To Next Transition

   For Paired Transitions

THDJ1

THDJ2

Note 3, 7, 8

and Рисунок 7-32

-3

-1

3

1

ns

ns

Data bit width distortion after SOP

TSOP

Note 3, 8 and Рисунок 7-32

-5

3

Hub EOP Delay Relative to tHDD

TEOPD

Note 3, 8 and Рисунок 7-33

0

15

ns

Hub EOP Output Width Skew

THESK

Note 3, 8 and Рисунок 7-33

-15

15

ns

Hub Timings  (Low Speed):

Driver Characteristics

  (Refer to Таблица 7-6)

Downstream ports configured as Low Speed

Hub Differential Data Delay

TLHDD

Note 4, 7, 8

and Рисунок 7-32

300

ns

Hub Differential Driver Jitter    (including cable)

Downstream:

   To Next Transition

   For Paired Transitions

Upstream:

   To Next Transition

   For Paired Transitions

TLDHJ1

TLDHJ2

TLUHJ1

TLUHJ2

Note 4, 7, 8

and Рисунок 7-32

-45

-15

-45

-45

45

15

45

45

ns

ns

ns

ns

Data bit width distortion after SOP

TSOP

Note 4, 8 and Рисунок 7-32

-60

45

Hub EOP Delay Relative to tHDD

TLEOPD

Note 4, 8 and Рисунок 7-33

0

200

ns

Hub EOP Output Width Skew

TLHESK

Note 4, 8 and Рисунок 7-33

-300

+300

ns

<


Note 1:     All voltages measured from the local ground potential, unless otherwise specified.

Note 2:     All timings use a capacitive load (CL) to ground of 50 pF, unless otherwise specified.

Note 3:     Full Speed timings have a 1.5 kW pull-up to 2.8 V on the D+ data line.

Note 4:     Low Speed timings have a 1.5 kW pull-up to 2.8 V on the D- data line.

Note 5:     Measured from 10% to 90% of the data signal.

Note 6:     The rising and falling edges should be smoothly transitioning (monotonic).

Note 7:     Timing difference between the differential data signals.

Note 8:     Measured at crossover point of differential data signals.

Note 9:     The maximum load specification is the maximum effective capacitive load allowed that meets the target hub VBUS droop of 330 mV.






Содержание раздела